397 research outputs found

    Master of Science

    Get PDF
    dissertationWireless communication systems in the terahertz (THz) frequency range promise to dramatically increase available bandwidth in the electromagnetic spectrum. These wireless systems will require filtering techniques capable of operating in this relatively unused part of the spectrum. In pushing towards more advanced filtering techniques, we demonstrate a terahertz filter design methodology based upon k-space that shows more complex filters such as band-pass, comb-pass and polarization-dependent filters. Using this design flow, we demonstrate: setting the center frequency and bandwidth in THz band-pass filters, controlling the individual magnitudes of each resonant peak in a comb filter, adjusting the transmittance of a filter at two different frequencies by spatially rotating the filter, and varying the transmittance at a single frequency by changing the polarization angle of incoming radiation. We believe this new k-space filter design methodology will help to create more complex filters that will find application in wireless THz communication systems

    Master of Science

    Get PDF
    thesisWireless communication systems in the terahertz (THz) frequency range promise to dramatically increase available bandwidth in the electromagnetic spectrum. These wireless systems will require filtering techniques capable of operating in this relatively unused part of the spectrum. In pushing towards more advanced filtering techniques, we demonstrate a terahertz filter design methodology based upon k-space that shows more complex filters such as band-pass, comb-pass and polarization-dependent filters. Using this design flow, we demonstrate: setting the center frequency and bandwidth in THz band-pass filters, controlling the individual magnitudes of each resonant peak in a comb filter, adjusting the transmittance of a filter at two different frequencies by spatially rotating the filter, and varying the transmittance at a single frequency by changing the polarization angle of incoming radiation. We believe this new k-space filter design methodology will help to create more complex filters that will find applicat ion in wireless THz communication systems

    Optimal Wavelength Selection for Optical Spectroscopy of Hemoglobin and Water within a Simulated Light-Scattering Tissue

    Get PDF
    An algorithm that selects optimal wavelengths for spectral fitting of diffuse light reflectance spectra using a nonnegative least squares method is presented. Oxyhemoglobin, deoxyhemoglobin, and water are considered representative absorbers, but the approach is not constrained or limited by absorber selection provided native basis spectra are available. The method removes wavelengths iteratively from a scattering-modulated absorption matrix by maximizing the product of its singular values and offers considerable improvements over previously published wavelength selection schemes. Resulting wavelength selections are valid for a broad range of optical properties and yield lower RMS errors than other wavelength combinations. The method is easily modified and broadly applicable to tissue optical spectroscopy. Adaptation of the algorithm to select optimal light-emitting diodes for fitting blood is described

    Weighting Function Effects in a Direct Regularization Method for Image-Guided Near-Infrared Spectral Tomography of Breast Cancer.

    Get PDF
    Structural image-guided near-infrared spectral tomography (NIRST) has been developed as a way to use diffuse NIR spectroscopy within the context of image-guided quantification of tissue spectral features. A direct regularization imaging (DRI) method for NIRST has the value of not requiring any image segmentation. Here, we present a comprehensive investigational study to analyze the impact of the weighting function implied when weighting the recovery of optical coefficients in DRI based NIRST. This was done using simulations, phantom and clinical patient exam data. Simulations where the true object is known indicate that changes to this weighting function can vary the contrast by 10%, the contrast to noise ratio by 20% and the full width half maximum (FWHM) by 30%. The results from phantoms and human images show that a linear inverse distance weighting function appears optimal, and that incorporation of this function can generally improve the recovered total hemoglobin contrast of the tumor to the normal surrounding tissue by more than 15% in human cases

    Characterizing Accuracy of Total Hemoglobin Recovery Using Contrast-Detail Analysis in 3D Image-Guided Near Infrared Spectroscopy with the Boundary Element Method

    Get PDF
    The quantification of total hemoglobin concentration (HbT) obtained from multi-modality image-guided near infrared spectroscopy (IG-NIRS) was characterized using the boundary element method (BEM) for 3D image reconstruction. Multi-modality IG-NIRS systems use a priori information to guide the reconstruction process. While this has been shown to improve resolution, the effect on quantitative accuracy is unclear. Here, through systematic contrast-detail analysis, the fidelity of IG-NIRS in quantifying HbT was examined using 3D simulations. These simulations show that HbT could be recovered for medium sized (20mm in 100mm total diameter) spherical inclusions with an average error of 15%, for the physiologically relevant situation of 2:1 or higher contrast between background and inclusion. Using partial 3D volume meshes to reduce the ill-posed nature of the image reconstruction, inclusions as small as 14mm could be accurately quantified with less than 15% error, for contrasts of 1.5 or higher. This suggests that 3D IG-NIRS provides quantitatively accurate results for sizes seen early in treatment cycle of patients undergoing neoadjuvant chemotherapy when the tumors are larger than 30mm

    Contrast-Detail Analysis Characterizing Diffuse Optical Fluorescence Tomography Image Reconstruction

    Get PDF
    Contrast-detail analysis is used to evaluate the imaging performance of diffuse optical fluorescence tomography (DOFT), characterizing spatial resolution limits, signal-to-noise limits, and the trade-off between object contrast and size. Reconstructed images of fluorescence yield from simulated noisy data were used to determine the contrast-to-noise ratio (CNR). A threshold of CNR=3 was used to approximate a lowest acceptable noise level in the image, as a surrogate measure for human detection of objects. For objects 0.5 cm inside the edge of a simulated tissue region, the smallest diameter that met this criteria was approximately 1.7 mm, regardless of contrast level, and test field diameter had little impact on this limit. Object depth had substantial impact on object CNR, leading to a limit of 4 mm for objects near the center of a 51-mm test field and 8.5 mm for an 86-mm test field. Similarly, large objects near the edge of both test fields required a minimum contrast of 50% to achieve acceptable image CNR. The minimum contrast for large, centered objects ranged between 50% and 100%. Contrast-detail analysis using human detection of lower contrast limits provides fundamentally important information about the performance of reconstruction algorithms, and can be used to compare imaging performance of different systems

    A Coupled Finite Element-Boundary Element Method for Modeling Diffusion Equation in 3d Multi-Modality Optical Imaging

    Get PDF
    Three dimensional image reconstruction for multi-modality optical spectroscopy systems needs computationally efficient forward solvers with minimum meshing complexity, while allowing the flexibility to apply spatial constraints. Existing models based on the finite element method (FEM) require full 3D volume meshing to incorporate constraints related to anatomical structure via techniques such as regularization. Alternate approaches such as the boundary element method (BEM) require only surface discretization but assume homogeneous or piece-wise constant domains that can be limiting. Here, a coupled finite element-boundary element method (coupled FE-BEM) approach is demonstrated for modeling light diffusion in 3D, which uses surfaces to model exterior tissues with BEM and a small number of volume nodes to model interior tissues with FEM. Such a coupled FE-BEM technique combines strengths of FEM and BEM by assuming homogeneous outer tissue regions and heterogeneous inner tissue regions. Results with FE-BEM show agreement with existing numerical models, having RMS differences of less than 0.5 for the logarithm of intensity and 2.5 degrees for phase of frequency domain boundary data. The coupled FE-BEM approach can model heterogeneity using a fraction of the volume nodes (4-22%) required by conventional FEM techniques. Comparisons of computational times showed that the coupled FE-BEM was faster than stand-alone FEM when the ratio of the number of surface to volume nodes in the mesh (Ns/Nv) was less than 20% and was comparable to stand-alone BEM ( ± 10%)

    Methodology Development for Three-Dimensional MR-Guided Near Infrared Spectroscopy of Breast Tumors

    Get PDF
    Combined Magnetic Resonance (MR) and Near Infrared Spectroscopy (NIRS) has been proposed as a unique method to quantify hemodynamics, water content, and cellular size and packing density of breast tumors, as these tissue constituents can be quantified with increased resolution and overlaid on the structural features identified by the MR. However, the choices in how to reconstruct and visualize this information can have a dramatic impact on the feasibility of implementing this modality in the clinic. This is especially true in 3 dimensions, as there is often limited optical sampling of the breast tissue, and methods need to accurately reflect the tissue composition. In this paper, the implementation and display of fully 3D MR image-guided NIRS is outlined and demonstrated using in vivo data from three healthy women and a volunteer undergoing neoadjuvant chemotherapy. Additionally, a display feature presented here scales the transparency of the optical images to the sensitivity of the measurements, providing a logical way to incorporate partial volume sets of optical images onto the MR volume. These concepts are demonstrated with 3D data sets using Volview software online

    Direct Regularization from Co-Registered Anatomical Images for MRI-Guided Near-Infrared Spectral Tomographic Image Reconstruction

    Get PDF
    Combining anatomical information from high resolution imaging modalities to guide near-infrared spectral tomography (NIRST) is an efficient strategy for improving the quality of the reconstructed spectral images. A new approach for incorporating image information directly into the inversion matrix regularization was examined using Direct Regularization from Images (DRI), which encodes the gray-scale data into the NIRST image reconstruction problem. This process has the benefit of eliminating user intervention such as image segmentation of distinct regions. Specifically, the Dynamic Contrast Enhanced Magnetic Resonance (DCE-MR) image intensity value differences within the anatomical image were used to implement an exponentially-weighted regularization function between the image pixels. The algorithm was validated using simulated reconstructions with noise, and the results showed that spatial resolution and robustness of the reconstructed images were significantly improved by appropriate choice of the regularization weight parameters. The proposed approach was also tested on in vivo breast data acquired in a recent clinical trial combining NIRST / MRI for cancer tumor characterization. Relative to the standard “no priors” diffuse recovery, the contrast of the tumor to the normal surrounding tissue increased from 2.4 to 3.6, and the difference between the tumor size segmented from DCE-MR images and reconstructed optical images decreased from 18% to 6%, while there was an overall decrease in surface artifacts

    Comparison of imaging geometries for diffuse optical tomography of tissue

    Get PDF
    Images produced in six different geometries with diffuse optical tomography simulations of tissue have been compared using a finite element-based algorithm with iterative refinement provided by the NewtonRaphson approach. The source-detector arrangements studied include (i) fan-beam tomography, (ii) full reflectance and transmittance tomography, as well as (iii) sub-surface imaging, where each of these three were examined in a circular and a flat slab geometry. The algorithm can provide quantitatively accurate results for all of the tomographic geometries investigated under certain circumstances. For example, quantitatively accurate results occur with sub-surface imaging only when the object to be imaged is fully contained within the diffuse projections. In general the diffuse projections must sample all regions around the target to be characterized in order for the algorithm to recover quantitatively accurate results. Not only is it important to sample the whole space, but maximal angular sampling is required for optimal image reconstruction. Geometries which do not maximize the possible sampling angles cause more noise artifact in the reconstructed images. Preliminary simulations using a mesh of the human brain confirm that optimal images are produced from circularly symmetric source-detector distributions, but that quantitatively accurate images can be reconstructed even with. a sub-surface imaging, although spatial resolution is modest. © 1999 Optical Society of America
    • …